TM 5-5420-279-23
(4)
Check the straightened area for cracks using the dye penetrant technique; refer to
(Section 3 c).
CAUTION
It is not permitted to apply further heat treatment after the temperature has been
raised once within the specified temperature range.
NOTE
If one or more cracks are detected, refer to repair procedure specified in Section 2 g.