TM 5-5420-279-23
b.
Install
(1)
Fit the stabilizer valve control block (1) to its mounting bracket and secure in place with the
four mounting bolts (3).
(2)
Fit the electrical cable to the proximity switch (2).
(3)
Fit the hydraulic hoses (5) to the stabilizer control valve block (1) at the positions noted
during removal.
(4)
Fit the hydraulic pipes (4) to the stabilizer control valve block (1) at the positions noted
during removal.
(5)
Fit the two operating cables at the control levers (6) and secure in place with the split pins
and cotter pins (not shown).
(6)
Remove the two operating cables by removing the split pins and cotter pins (not shown) at
the control levers (6).
c.
Follow on tasks
(1)
Switch the battery shutoff switch to the on position.
(2)
Check the operation of the crane stabilizers in accordance with the operator's manual TM
5-5420-279-10.
(3)
Check for hydraulic oil leaks.