TM 5-5420-279-23
b.
Test
(1)
Carry out a resistance check on across pins (5) and (6) of the solenoid dump valve (1).
(2)
The reading should be between 19 - 23 ohms.
(3)
If the reading taken is below 19 ohms change the solenoid dump valve (1).
c.
Install
(1)
Fit the solenoid dump valve (1) to the crane valve control block mounting (7).
(2)
Secure the solenoid dump valve (1) with the four bolts (3).
(3)
Fit the cable plug (2) to the solenoid dump valve (1) and secure in place with the screw (4).
d.
Follow on tasks
(1)
Switch the battery shutoff switch to the on position.
(2)
Check the operation of the crane in accordance with the operator's manual TM 5-5420-
279-10 and check for hydraulic oil leaks.
6-226
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |