a.
Remove
(1)
Deploy the stabilizer extension (4) to gain access to the stabilizer proximity switch (1).
(2)
Measure the exposed thread of the proximity switch at the crane base.
(3)
Locate and remove the electrical cable (3) connected to the proximity switch (1).
(4)
Turn the proximity switch lock nut (2) one full turn counter clockwise.
(5)
Remove the proximity switch (1).
(6)
Check the electric cable for damage.
(7)
Replace components as required.
b.
Install
(1)
Fit the proximity switch (1) to the crane base.
(2)
Adjust the proximity switch (1) so that the exposed thread showing is equal to the
measurement taken during removal.
(3)
Tighten the lock nut (2).
(4)
Fit the electrical cable to (3) the proximity switch (1).
c.
Follow on tasks
(1)
Switch the battery shutoff switch to the on position.
(2)
Test the operation of the proximity switch in accordance with the operator's manual
TM 5-5420-279-10.