TM 5-5420-279-23
a.
Remove
(1)
Remove stabilizer foot (1) in
accordance with unit
maintenance procedure 5-021.
(2)
Lower stabilizer leg (2) until the
cylinder location pin (3) is visible.
(3)
Remove the snap ring (4) from
the cylinder location pin (3).
(4)
Support the weight of the
stabilizer leg (2).
(5)
Remove the cylinder location pin
(3) and retain the spacer (4).
(6)
De-pressurize hydraulic system.
Refer to unit maintenance 5-118.
(7)
Note the position of and
disconnect the hydraulic pipes (6)
connected to the stabilizer leg
cylinder.
(8)
Remove the hydraulic extension
unions (7).
(9)
Remove the stabilizer leg cylinder
pin locking plate bolts (8) and
remove the locking plates (9).
(10)
Remove the boss bolts (10)
securing the stabilizer leg cylinder
pin boss (11) and remove the
boss (11).
(11)
Remove the spacers (12) on the
stabilizer leg cylinder pin (13) and
remove the stabilizer leg cylinder
pin (13).
(12)
Push the stabilizer leg (2) up
through the outer leg section (14)
until the lower bearing pads
mounted in the outer leg section
(14) are accessible.
(13)
Remove the screws retaining the
lower bearing pads and remove
the bearing pads.
WARNING
CRUSH INJURY. THE STABILIZER
LEG AND STABILIZER LEG
CYLINDER ARE HEAVY.
6-11
|