Using a small screwdriver remove some of the energy chain spreader bars on the radius to
allow the hydraulic pipe to be pulled back when disconnecting.
(19)
Disconnect hydraulic quick release couplings inside both sides of slide frame.
(20)
Disconnect the mil-coupling on the moving slide frame junction Box. Disconnect the earth
cable on the moving slide frame junction box, remove any cable ties to slide frame and roll
back cable to dove tail bracket and secure.
20
MF-03
MOVING
SLIDE FRAME
JUNCTION BOX
MF-01
686A671
(21)
Remove two bolts holding the dovetail brackets to slide frame.
(22)
Lift to disconnect dovetail brackets from the slide frame to disconnect energy chain from
slide frame.
(23)
Unclip A-Frame folded walkways and swing, out hold in place with ladder retaining straps
this is to stop it being compressed by the lifting slings.