TM 5-5420-279-23
2
3
1
a.
Remove
(1)
De-pressurize the hydraulic system. Refer to unit maintenance procedure 5-118.
(2)
Remove the four screws and lock washers securing the stabilizer manifold cover (not
shown). Discard the lock washers.
(3)
Remove the cover.
(4)
Remove the four screws (9) securing the stabilizer manual control valve (8) to the valve
adapter plate (5).
(5)
Remove and the four seals (6) fitted between the stabilizer manual control valve (8) and
the valve adapter plate (5).
(6)
Remove the four screws (7) securing the valve adapter plate (5) and sandwich body (3) to
the stabilizer manifold assembly (1).
(7)
Remove the seals (4 and 2).
(8)
Note the position of and remove the cartridge throttle valve (10) from the sandwich body (3)
P (pressure) port.
(9)
Check all threaded components for damage and wear.
(10)
Clean the cartridge throttle valve (10).
(11)
Replace components as necessary.