TM 5-5420-279-23
2
1
3
a.
Remove
(1)
De-pressurize the hydraulic system. Refer to unit maintenance procedure 5-118.
(2)
Remove the four screws and lock washers securing the stabilizer manifold cover (not
shown). Discard the lock washers.
(3)
Remove the cover.
(4)
Remove the four screws (3) securing the stabilizer manual control valve (2) to the stabilizer
manifold (1).
(5)
Remove and discard the four seals fitted between the stabilizer manual control valve (2)
and the stabilizer manifold (1).
b.
Install
(1)
Fit four new seals to the stabilizer manifold control valve (2).
(2)
Fit the stabilizer manual control valve (2) to the stabilizer manifold (1) and secure in place
with the four screws (3).
(3)
Check the operation of the stabilizer manifold assembly (1) and check for leaks.
(4)
Apply thread locking compound to the eight screws for the stabilizer manifold cover.
(5)
Fit the stabilizer manifold cover and secure in place with the four screws and lock washers.
5-385
|