TM 5-5420-279-23
3
4
2
1
a.
Remove
(1)
De-pressurize the hydraulic system. Refer to unit maintenance procedure 5-118.
(2)
Remove the four screws and lock washers securing the stabilizer manifold cover (not
shown). Discard the lock washers.
(3)
Remove the cover.
(4)
Remove hydraulic hose (2) connected to the synchronizing flow divider (3).
(5)
Remove the synchronizing flow divider (3) and seal (4).
(6)
Check the condition of the hydraulic oil seal (4) and replace as necessary.
b.
Install
(1)
Fit the synchronizing flow divider (3) and seal (4) to the stabilizer manifold assembly (1).
(2)
Fit the hydraulic hose (2) to the synchronizing flow divider (3).
c.
Follow on tasks
(1)
Check the operation of the stabilizer manifold assembly (1) and check for leaks.
(2)
Apply thread locking compound to the eight screws for the stabilizer manifold cover.
(3)
Fit the stabilizer manifold cover and secure in place with the four screws and lock washers.
5-383