a.
Remove
(1)
De-pressurize the hydraulic system. Refer to unit maintenance procedure 5-118.
(2)
Note the position of and remove the hydraulic hoses (2) connected to the shuttle valve (1).
NOTE
There may be two or more hydraulic hoses connected to the shuttle valve under repair.
(3)
Remove the two bolts and washers (3) securing the shuttle valve (1) to its mounting.
b.
Install
(1)
Apply thread locking compound to the bolts.
(2)
Secure the shuttle valve (1) to its mounting with the bolts and washers (3).
(3)
Fit the hydraulic hoses (2) to the shuttle valve (1) in the positions noted during removal.
(4)
Check the operation of the system under repair.