Click here to make tpub.com your Home Page

Page Title: Install
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-5420-279-23
(10)
To remove the circuit breaker reset
button (13), turn the locking screw (10)
counter-clockwise.
(11)
Remove the Locking plate (11).
Remove the circuit breaker reset button
(13) complete with seal (12).
b.
Install
(1)
Fit the circuit breaker reset button (13)
complete with seal (12) to the operator's
panel (4).
(2)
Fit the locking plate (11) to the circuit
breaker reset button (13).
(3)
Turn the locking screw (10) clockwise
and tighten.
(4)
Fit the circuit breaker (5) to the interface
enclosure bracket (6) and secure in
place with the nut and washer (7).
(5)
Fit the two cables (9) with the screws (8)
in the positions noted during removal.
Circuit Breaker Reset Button
(6)
Fit new cable ties to the operator's panel (4).
(7)
Fit the harnesses to the operator's panel in the positions noted during removal.
(8)
Fit the twelve plugs in the positions marked during removal.
(9)
Fit the operator's panel (4) to the interface enclosure (1) and secure in place with the
sixteen screws and washers (3).
c.
Follow on tasks
(1)
Switch the battery shutoff switch to the on position.
(2)
Operate the launcher and check all systems for correct operation.
5-334

Privacy Statement - Press Release - Copyright Information. - Contact Us