Click here to make tpub.com your Home Page

Page Title: Remove
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-5420-279-23
a.
Remove
(1)
Open the cover (2) of the interface enclosure (1).
(2)
Remove the sixteen screws and washers (3) securing the operator's panel (4) to the
interface enclosure (1).
(3)
Remove to one side, and support, the operator's panel (4).
(4)
Remove the cable ties securing the two harnesses and twelve plugs to the operator's panel
(4).
(5)
Using a suitable marker, mark the twelve plugs and their positions on the operator's panel
(4).
(6)
Remove the operator's front panel (4).
(1)
Locate the emergency stop switch (5).
(2)
Note the position of and remove the quick release plug (12) from the printed circuit board.
(3)
If required, note the positions of the cables (13) and remove them from the contactor (10)
by turning the securing screws (14) counter-clockwise until the cables (13) are released.
(4)
Press down on the contactor release lever (11) and remove the two contactors (10 and 15)
from the carrier (9).
(5)
Remove the carrier (9) from the emergency stop switch (5).
(6)
Turn the lock screw (8) counter-clockwise to release the lock plate (7).
(7)
Remove the lock plate (7) from the emergency stop switch (5).
(8)
Remove the emergency stop switch (5) complete with seal (6).
b.
Install
(1)
Fit the emergency stop switch (5) complete with seal (6) to the operator's panel (4).
(2)
Fit the lock plate (7) to the emergency stop switch (5).
(3)
Turn the lock screw (8) clockwise and tighten.
(4)
Fit the carrier (9) to the emergency stop switch (5).
(5)
Fit the two contactors (10 and 15) to the carrier (9).
(1)
Fit the cables (13) to the contactor (10) and secure in pace with the securing screws (14) in
the positions noted during removal.
(2)
Fit new cable ties to the operator's panel (4).
(3)
Fit the harnesses to the operator's panel in the positions noted during removal.
(4)
Fit the twelve plugs in the positions marked during removal.
(5)
Fit the operator's panel (4) to the interface enclosure (1) and secure in place with the
sixteen screws and washers (3).
c.
Follow on tasks
(1)
Switch the battery shutoff switch to the on position.
(2)
Operate the launcher and check the bridge for correct operation.
5-321

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business