TM 5-5420-279-23
a.
Remove
(1)
Note the position of and remove the electrical harnesses to the interface enclosure (1).
(2)
Remove the nut (5) and lock washer (6), ground lead (8), washer (7) and bolt (4) at the
interface enclosure (1). Discard the lock washer.
(3)
Remove the six bolts (3) and lock washers (9) securing the interface enclosure (1) to the
chassis-mounting bracket (2). Discard the lock washers.
(4)
Remove the interface enclosure (1).
(5)
Examine all threaded components for wear and damage.
(6)
Check the electrical harnesses for damage.
(7)
Change components as required.
b.
Install
(1)
Apply thread-locking compound to the bolts (3).
(2)
Fit the interface enclosure (1) to the chassis-mounting bracket (2) with the six bolts (3) and
new lock washers (9).
(3)
Fit the bolt (4), washer (7), ground lead (8) new lock washer (6) and nut (5) at the interface
enclosure (1).
(4)
Fit the electrical harnesses to interface enclosure (1) to the positions noted during removal.
5-310
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |