TM 5-5420-279-23
a.
Remove
(1)
Remove the electrical cables (7) connected to the limit switches (3).
(2)
Check that the shoot bolt handle (8) is in its lowest position as shown.
(3)
Remove the bolts (4), nyloc nuts (5) and washers (6) securing the limit switch (3) to the
limit switch mounting (9). Discard the nyloc nuts.
(4)
Remove the limit switch (3).
(5)
If required the limit switch cam/shoot bolt (2) can be removed by unscrewing the shoot bolt
handle (8).
(6)
Check all threaded components for wear and damage.
(7)
Check the electrical cable (7) and plug for damage.
(8)
Replace components as necessary.
b.
Install
(1)
If previously removed, fit the limit switch cam/shoot bolt (2) to the relax mechanism (1).
(2)
Fit the shoot bolt handle (8) to the limit switch cam/shoot bolt (2). Ensure that the shoot bolt
handle (8) is in its lowest position.
(3)
Fit the limit switch (3) to the mounting bracket (9).
(4)
Secure the limit switch (3) with the bolt (4), washer (6) and new nyloc nuts (5).
(5)
Fit the electrical cable (7) to the limit switch (3).
c.
Follow on tasks
(1)
Switch the battery shutoff switch to the on position.
(2)
Check the operation of the limit switch cam/shoot bolt (2) and limit switch (3).
5-302
|