TM 5-5420-279-23
5
2
1
3
4
7
6
A-Frame Deployed - Limit Switch
(3)
With the A-Frame fully deployed, loosen the adjuster screw (8) on the A-Frame parked limit
switch (2).
(4)
Set the operating arm (9) to an angle of 30 degrees from the A-Frame cross beam. Tighten
the adjuster screw (8).
1
9
2
4
3
8
A-Frame Parked - Limit Switch
5-113
|