a.
Remove
(1)
Remove the hydraulic motor (2) in accordance with unit maintenance procedure 5-017.
NOTE
The inner and outer Guide Roller Assembly Base mountings are different. The inner
A-Frame Guide Roller assembly has six mounting bolts and the outer Guide Roller
assembly has four mounting bolts.
(2)
Remove the four or six mounting bolts (3) and lock washers (4) securing the guide roller
assembly (1) to the A-Frame. Discard the lock washers (4).
NOTE
The Guide Roller Assembly is additionally located on the A-Frame with roll pin(s) and may
need to be pried away from the A-Frame.
(3)
Remove the guide roller assembly (1) and place on a suitable working surface.
(4)
Remove and retain the locating roll pin(s).
(5)
Remove the four end cap screws and remove the end cap (5) from the small housing (6).
(6)
Remove the four screws securing the small housing (6) to the base (8).
NOTE
The Small Housing (6) is additionally located on the Base (8) by two roll pins.
(7)
Remove the small housing (6).
(8)
Remove the four screws securing the large housing (7) to the base (8).
NOTE
The Large Housing (7) is additionally located on the Base (8) by two roll pins.
(9)
Remove the large housing (7).
(10)
Lift the support roller assembly complete with shaft and bearings from the base (8).