Click here to make tpub.com your Home Page

Page Title: Gauge points TPA2 & TPB2 and/or TPB3 on the Stabilizer Manifold, TPPL & TPLS on the Interface Manifold
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-5420-279-23
NOTE
650 psi (4500 kPa) is the pump standby (off load) pressure.
e. If there is no LS (load sense) pressure at the Interface Manifold then the shuttle valve(s) in
the pipe work are at fault.
f.
If you get 650 psi (4500 kPa) at A and B this means solenoid valve is OK.
g. If pressure at LS pressure gauge is Zero, the Compensator is open so the back to back
check valves are at fault.
TSUM 2-001 A-Frame Unfold (13)(Part2),
TSUM 2-002 Uneven A-Frame Unfold (13)
TSUM 2-027 A-Frame Fold (Park)(122)(Part 2) and
TSUM 2-027 Uneven A-Frame Fold (Park)(122)
Gauge points TPA2 & TPB2 and/or TPB3 on the Stabilizer Manifold, TPPL & TPLS on the
Interface Manifold.
Gauge
Nothing
Operate Valve SV20to put
Operate Valve SV20 to put
Operated
Pressure to `A' Port (A-Frame
Pressure to `B' Port (A-Frame
Fold Park button depressed on
Fold Deploy button depressed
Operator Panel)
on Operator Panel)
653 psi
3480 psi
3480 psi
P
(4500 kPa)
(24000 kPa)
(24000 kPa)
Unless limited
TPA2
2900 psi
by relief or
0 psi
0 psi
(20000 kPa)
reducing valve
Unless limited by
TPB2
2900 psi
relief or reducing
and/or
0 psi
0 psi
(20000 kPa)
valve
TPB3
2900 psi
2900 psi
TPLS
0 psi
(20000 kPa)
(20000 kPa)