TM 11-6625-601-12
1-7. Description of Maintenance Kit Elec-
for testing the RT-348/ARC-54 of the G-3835/ARC-
tronic Equipment MK-733/ARC-54
54.
e. Cable Assembly, Special Purpose, Electrical
CX-9072/ARC-54 is used to interconnect the TS-
The MK-733/ARC-54 is composed of the TS-1967/
1967/ARC-54 and the RT-348/ARC-54. The CX-
ARC-54, the SM-349/ARC-54, the CW-711/ARC-54,
9072/ARC-54 provides control circuit and coaxial
adapters, and extender cables (para 1-6). The main
connections for testing the RT-348/ARC-54.
panel of the MK-733/ARC-54 is formed by the
TS-1967/ARC-54 and the SM-349/ARC-54 installed
(1 ft) is used to interconnect the RF circuits
in a fiberglass case. Operating controls, connec-
between the TS-1967/ARC-54 and the unit under
tors, and indicators are mounted on the front panel
test. The CG-409G/U consists of RF Cable RG-58/U
of the TS-1967/ARC-54 and the SM-349/ARC-54.
with a BNC connector on each end.
The SM-349/ARC-54, normally plugged into the
g. Cable Assembly, Power, Electrical CX-11136/
front panel of the TS-1967/ARC-54, can be removed
ARC-54 is used to interconnect the TX-1967/ARC-
and substituted for the RT-348/ARC-54 when
54 to the primary power source. One end of the
operational checks are performed in the aircraft. A
cable has a plug that connects to POWER 28 VDC
sliding connector bracket, on the rear of the
jack J32 on the TS-1967/ARC-54. The other end of
SM-349/ARC-54 (fig. 2-3), is used to adapt the
the cable has three alligator clips that connect to
SM-349/ARC-54 to the RT-348/ARG54 shockmount
the power source.
(Mounting MT-1535/ARC-54). Locking pins hold
h. Adapter, Connector UG-1678/U is used to
the bracket in place in either the extended or
adapt the RF connector of the CU-942/ARC-54 (or
retracted position. Indicator ID-48/ARN, mounted
CU-943/ARG-54) to a BNC connector.
on the front panel of the TS-1967/ARC-54 (fig. 2-2),
i. Extender, Module MX-4930/ARC-54 is used to
is used to display left, right, or over-target homing
extend the fixed intermediate frequency (IF)
information during homing tests. A blower in the
module from the RT-348/ARC-54. The test jacks on
TS-1967/ARC-54 provides forced air ventilation
the MX-4930/ARC-54 provide access to the module
during transmit tests. When prepared for transit,
connector pins.
the compartment cover of the CW-711/ARC-54 is
j. Extender, Module MX-4931/ARG-54 is used to
closed. The case containing the SM-349/ARC-54
extend the homer module from the RT-348/ARC-
and the TS-1967/ARC-54 is placed in the recessed
54. The test jacks on the MX-4931/ARC-54 provide
area of the CW-71l/ARG54 and held in place by
access to the module connector pins.
four latches.
k. Extender, Module MX-4932/ARC-54 is used to
1-8. Description of Minor Components
extend the power supply module from the RT-
348/ARC-54. The test jacks on the MX-4932/ARC-54
provide access to the module connector pins.
Special features of the minor components of the
l. Extender, Module MX-4933/ARC-54 is used to
MK-733/ARC-54 are listed below:
extend the RF chassis from the RT-348/ARC-54.
a. Cover, Maintenance Kit CW-711/ARC-54 is of
The test jacks on the MX-4933/ARC-54 provide
lightweight rugged construction and contains all
access to the RF chassis connector pins.
of the accessories for the MK-733/ARC-54. Com-
m. Extender Module MX-4934/ARC-54 is used
partments are provided for storing the adapters,
to extend the SEL CALL transmit audio, or the
cable assemblies, and running spares.
receive audio module from the RT-348/ARC-54.
The test jacks on the MX-4934/ARC-54 provide
quency (RF) signal transmission during bench test
access to the module connector pins.
of the RT-348/ARC-54. The AS-14871ARC-54 con-
n. Tool Kit, Electronic Equipment TK-156/ARC-
nects to ANT jack J7 on the TS-1967/ARC-54.
54 (fig. 1-2) contains tools used for calibration,
c. Cable Assembly, Special Purpose, Electrical
alignment, and maintenance of the TS1967/ARC-
CX-9070/ARC-54 is used to interconnect the TS-
54 and the RT-348/ARC-54. The tools are supplied
1967/ARC-54 and the CU-942/ARC-54 (or CU-943/
in a cloth container.
ARC-54). The CX-9070/ARC-54 provides control
circuit connections for testing the CU-942/ARC-54
1-9. Additional Equipment Required
or CU-943/ARC-54).
d. Cable Assembly, Special Purpose, Electrical
a. General. The test equipment listed in b below is
CX-9071/ARC-54 is used to interconnect the TS-
required for use with the MK-733/ARC-54 when
1967/ARC-54 and the G3835/ARC-54. The CX-
the tests described in paragraphs 2-7 through 2-10
9071/ARC-54 provides control circuit connections
are performed.
Change 3 1-3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |