TM 11-6625-564-45
control setting
Step
NO.
Test Equipment
Test procedure
b. Connect ME-30(*)/U to
ME-30(*)/U
ME-30(*)/U must read
2 vac minimum.
terminals 2 and 4 of
Set to measure
HEADSET H-101A/U
minimum of 2
jack J4 on radio set
vac.
simulator.
Radio set simula-
tor
POWER: RESET
ON.
13
Controls remain as at end
None.
a. Connect 5-ohm output of
TS-421/U
of step 12.
matching pad to ter-
Controls remain as
minals 1 and 3 of
at end of step
HEADSET H-101A/U
12.
jack J4 on radio set
ME-30(*)/U
simulator. Connect ME
Set to measure
maximum of 4
30(*)/U to red MAIN
vac.
AUDIO test jack and
Radio set simula-
ground on test unit.
tor
b. Vary test unit AUDIO
ME-30(*)/U must vary
Controls remain as
GAIN control, and ob-
from 0 to 3.8 vac.
at end of step
serve ME-30(*)/U.
12.
c. Connect ME-30 (*)/U
ME-30(*)/U must read
between terminals 2
0.92 vac minimum.
and 4 of HDSET
H-101A/U jack J9
on test unit. Rotate
test unit AUDIO
GAIN control fully
clockwise.
74
|