TM 11-6625-2609-34
c. Procedure.
Control settings
Steps
Test procedure
Test equipment
No.
Equipment under ted
Performance standard
1
AN/ARC-134
Set all test panel switches
a. Apply primary operat- a. None.
Set meter switch to
ing power to test
to OFF and set EXT.
MOD I.
equipment and main-
SQUELCH CONTROL
AN/URM-120
fully counterclockwise.
tenance kit.
Set above 25.
b. Set maintenance kit b. None.
ME-30A/U
POWER CB circuit
Set range scale to 10
breaker to ON, VHF
Volta
COMM OFF-PWR
AN/URM-127
switch to PWR, and
V H F COMM fre-
Set frequency to 1000
quency-selector
Hz.
switches to 132.500
MHz. Allow a few
minutes for warmup
before proceeding.
C. Set maintenance kit c. Modulation should be
indicated by a meter
PTT switch to ON
deflection on the
and increase AN/
ME-30A/U.
URM-127 output
level.
d. Set PTT switch to
OFF.