PROCEDURE
TROUBLESHOOTING
REFERENCE
a.
ENG FIRE TEST switches - Hold switches
to DET position, check that FIRE PULL
handle warning annunciators and MASTER
WARNING annunciators illuminate.
b.
ENG FIRE TEST switches - Hold switches
to EXT position, check that SQUIB OK and
EXTGH DISCH annunciators and MASTER
CAUTION annunciators illuminate.
NOTE
If MASTER WARNING is canceled between tests, it
may not re-illuminate.
*19.
Stall and gear warning system - Check
as follows:
a.
STALL WARN TEST switch - TEST. Check
that warning horn sounds.
b.
LDG GEAR WARN TEST switch - TEST.
Check that warning horn sounds and that
the LDG GEAR CONTR handle warning
lights illuminate.
*20.
Flaps - Check in full down and full up positions.
21.
BATTERY switch - As required.
*22.
Seat belts - Check for security and proper
connections.
*23.
Toilet - Check condition.
*24.
Emergency equipment - Check that all required
emergency equipment is available and that fire
extinguishers and