Inspection and Repair.
I
FRAME 1
1.
Check that drive end housing (1) has no cracks or breaks. If end housing is
damaged, generator is nonrepairable.
Measure bearing bore (2) of drive end housing (1). Bore must be 2.4412 to
2.
2.4407 inches. If bore is not within given limits, generator is nonrepairable.
Check that rectifier mounts (3) are not cracked or broken and that they have
3.
no damaged threads.
Check that connector (4) has no damage, stripped threads, or loose or frayed
4.
wiring.  If connector is damaged, generator is nonrepairable.
5.
Check that screws (5) and washers (6) do not have damaged heads and that
they are not broken. If parts are damaged, get new ones.
6.
Check that terminal cover (7) is not cracked or broken. If terminal cover is
damaged, get a new one.