Fuel Pump and Ignition for Top Mounted-Covered Flame Heater
Up
TM-9-2815-210-34-2-2 Engine Assembly Diesel (MULTIFUEL): Naturally Asspirated or Turbocharged Fuel-Injected Water-Cooled 6-Cylider Manual
Next
FRAME 3 - TM-9-2815-210-34-2-20745
TM 9-2815-210-34-2-2
FRAME 2
NOTE
T w o types of top mounted-covered flame heater fuel
p u m p and ignition units have been used on these en-
g i n e s .  Type A and type B assemblies have the same
parts and are put back in the same way.
Put 9 0 elbow (1) and 45 elbow (2) into flame heater fuel pump (3).
1.
P u t on two spring clamps (4),
2.
Put f u e l pump (3) in place.
Put w i r i n g harness (5) in place. Screw on a n d t i g h t e n n u t ( 6 ) .
3.
Put f l a m e heater fuel pump-to-flame heater n o z z l e tube (7) in place.
Screw
4.
i n and tighten fitting `nut'(8).
P u t flame heater fuel pump-to-flame heater f u e l filter tube ( 9 ) in place.
5.
S c r e w in and tighten fitting nut (10).
GO TO FRAME 3
5-114