Quantcast Piston Cooling Nozzles Adjustment (Engines LDS-465-1A and LDS-465-2).

 

Click here to make tpub.com your Home Page

Page Title: Piston Cooling Nozzles Adjustment (Engines LDS-465-1A and LDS-465-2).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
FRAME 4 - TM-9-2815-210-34-2-20671
Up
TM-9-2815-210-34-2-2 Engine Assembly Diesel (MULTIFUEL): Naturally Asspirated or Turbocharged Fuel-Injected Water-Cooled 6-Cylider Manual
Next
Figure 5-2. Oil Pressure Regulator Valve Adapter Fabrication Instructions.
TM 9-2815-210-34-2-2
b.
P i s t o n Cooling Nozzles Adjustment (Engines LDS-465-1A and LDS-465-2).
FRAME 1
NOTE
T e l l machine shop to make adapter with gasket (1).
U s e two oil pressure regulator valve adapter capscrews
(2) to hold adapter (1).
1.
P u t fabricated adapter with gasket (1) in place over nozzle gallery supply
h o l e .  P u t in two capscrews (2).
2.
P u t oil supply line (3) on adapter (1). Put other end of oil supply line on
o u t l e t side of oil pressure tank (4).
Fill oil pressure tank (4) with OE/HDO 10 engine oil.
3.
NOTE
Air pressure supply must be set to 80 psi.
H o o k oil pressure tank (4) to air pressure supply.
4.
GO TO FRAME 2