Page Title: FLAME HEATER FUEL PUMP (COVERED SYSTEM).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2815-210-34-2-2
Repair.
c.
( 1 ) Repair minor damage to ignition unit by filing burrs on threads.
( 2 ) If damage cannot be repaired, throw unit away and get a new one.
4-66. FLAME HEATER FUEL PUMP (COVERED SYSTEM).
a. Cleaning.
FRAME1
Cap electrical receptacle connection (1).
1.
P l u g fuel inlet (2) and outlet (3) ports.
2.
WARNING
Dry cleaning solvent is flammable. Do not use near an
o p e n flame. Keep a fire extinguisher nearby when sol-
v e n t is used. Use only in well-ventilated places. Fail-
u r e to do this may result in injury to personnel and
d a m a g e to equipment.
CAUTION
Fuel pump should not be dipped in cleaning solvent.
E l e c t r i c a l parts can be damaged.
C l e a n fuel pump with cloth dipped in dry cleaning solvent.
3.
END OF TASK