(2)
Cleaning.
FRAME 1
WARNING
D r y cleaning solvent is flammable. Do not use near
an open flame.  K e e p a fire extinguisher nearby when
s o l v e n t i s u s e d .  U s e only in well-ventilated places.
F a i l u r e to do this may result in injury to personnel
a n d damage to equipment.
CAUTION
Do not put hydraulic pump (1) in dry cleaning solvent,
P a r t s can be damaged and pump will not run properly.
1.
C l e a n hydraulic pump (1) with dry cleaning solvent. Use a stiff brush to
take off carbon and sludge. Dry with clean cloth.
C l e a n three elbows (2, 3, and 4) , adapter (5), drive gear (6), pump adapter
2.
(7), two nuts (8), woodruff key (9), and nut (10) in dry cleaning solvent.
U s e a stiff brush to take off carbon and sludge. Dry with clean cloth.
END OF TASK
NOTE
PARTS WITHOUT CALLOUTS ARE SHOWN ONLY FOR
REFERENCE PURPOSES.
TA 121138