Quantcast Inspection and Repair. - TM-9-2815-210-34-2-20219

 

Click here to make tpub.com your Home Page

Page Title: Inspection and Repair.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
Cleaning. - TM-9-2815-210-34-2-20218
Up
TM-9-2815-210-34-2-2 Engine Assembly Diesel (MULTIFUEL): Naturally Asspirated or Turbocharged Fuel-Injected Water-Cooled 6-Cylider Manual
Next
FRAME 2 - TM-9-2815-210-34-2-20220
TM 9-2815-210-34-2-2
I n s p e c t i o n and Repair.
c.
FRAME
1
NOTE
T w o types of oil pressure regulator (1) have been
u s e d on these engines.  This task is the same
f o r both except as noted.
1.
C h e c k that housing (1) is not cracked. If housing is cracked, throw it
away and get a new one.
WARNING
Dry cleaning solvent is flammable. Do not use near an
o p e n flame.  Keep a fire extinguisher nearby when solvent
i s used.  Use only in well-ventilated places.  Failure to
d o this may result in injury to personnel and damage
t o equipment.
2.
C h e c k that mounting surface of housing (1) has no nicks, scratches or burrs.
F i x nicks, scratches, and burrs with a fine mill file or crocus cloth dipped in
dry cleaning solvent.
3.
C h e c k that oil passages (2) are clean and free from dirt. Clean out blocked
or dirty oil passages. Refer to para 4-3.
4.
Check that two plunger bores (3) are not scored or worn. If plunger bores
a r e scored or worn, throw away housing and get a new one.
5.
C h e c k that threaded holes in housing (1) are not damaged. Fix minor thread
damage with a tap.
GO TO FRAME 2