Click here to make tpub.com your Home Page

Page Title: AIR PRESSURE TEST STE/ICE-R TEST #50
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-3
WARNING
Wear protective goggles to protect against
possible injury from release of high pressure
air. Failure to comply may result in injury to
personnel.
NOTE
Tag air hose and connection point prior to
disconnecting
AIR PRESSURE TEST STE/ICE-R TEST #50
(1) Open LH and RH catwalks.
(2) Disconnect air hose from pneumatic
manifold solenoid L17 port 1.
(3) Remove tube nipple from M1089 30K
winch pneumatic test adapter.
(4) Connect M1089 30K winch pneumatic test
adapter on pneumatic manifold solenoid
L17 port 1.
(5) Install STE/ICE-R 0-1000 PSI transducer on
M1089 30K winch pneumatic test adapter.
(6) Start engine (TM 9-2320-366-10-1) and
allow vehicle to build air pressure.
(7) Position MAIN WINCH RH FREESPOOL
switch to ON.
(8) Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(9) If 75-120 PSI (518-827 kPa) is not present,
repair 30K winch pneumatic solenoid or
replace solenoid L17 (para 17-29).
(10)) Shutdown engine (TM 9-2320-366-10-1).
(11) Drain air tanks (TM 9-2320-366-10-1).
(12) Position MAIN WINCH RH FREESPOOL
switch to OFF.
(13) Disconnect M1089 30K winch pneumatic
test adapter from pneumatic solenoid L19
port 1.
(14) Connect air hose to pneumatic solenoid
L17 port 1.
(15) Close LH and RH catwalks.
Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business