x3. NO POWER TO ENHANCED POSITION LOCATION REPORTING SYSTEM (EPLRS) (CONT)
TEST OPTIONS
TEST OPTIONS
2.
Continuity Test or
Circuit breaker CB5 is not
STE/ICE-R Test #91
tripped.
Is continuity present through
REASON FOR QUESTION
circuit breaker CB5?
POSSIBLE PROBLEMS
If continuity is not present,
circuit breaker CB5 is faulty.
Faulty circuit breaker CB5.
If continuity is present,
Faulty digitization rack power
perform Special Purpose Kits
supply.
Troubleshooting task x1. No
Power to Digitization Rack.
NO
Replace circuit breaker CB5
YES
(para 20-80).
Perform Special Purpose Kit
Troubleshooting task x1. No Power
to Digitization Rack.