TM 9-2320-366-20-2
TM
CONTINUITY TEST
(1)
Remove personnel heater to gain access
(para 18-9).
(2)
Disconnect connector P912A from connector
J912.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
relay K15 socket 87A.
(5)
Connect negative (-) probe of multimeter to
connector P912A-15 and note reading on
multimeter.
(6)
If continuity is not present, repair wire 1811
(para 2-45) or replace WTEC II dashboard
cable assembly (para 7-10) or WTEC III
dashboard cable assembly (para 7-11).
(7)
If continuity is present, repair wire 1811
(para 2-45) or replace oil cooler fan cable
assembly (para 7-136).
(8)
Install relay K15 in PDP.
(9)
Connect connector P912A to connector J912.
(10)
Install personnel heater (para 18-9).