Quantcast VOLTAGE TEST - TM-9-2320-366-20-20425

 

Click here to make tpub.com your Home Page

Page Title: VOLTAGE TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
M1089 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE FROM REMOTE CONTROL
Up
TM-9-2320-366-20-2 M1083 Series 5-Ton 6 x 6 Medium Tactical Vehicles (MTV) Manual
Next
M1089 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE FROM REMOTE CONTROL (CONT) - TM-9-2320-366-20-20426
TM 9-2320-366-20-2
TM
WARNING
Remove rings, bracelets, watches,
necklaces, and any other jewelry
before working around vehicle.
Jewelry can catch on equipment
and cause injury or short across
electrical circuit and cause severe
burns or electrical shock.
VOLTAGE TEST
(1)
Remove cover from left or right remote control
cable bulkhead connector.
(2)
Set multimeter to volts dc.
(3)
Connect positive (+) probe of multimeter to
pin E of remote control bulkhead connector.
(4)
Connect negative (-) probe of multimeter to
pin B of remote control bulkhead connector.
(5)
Position MAIN POWER switch to ON
(TM 9-2320-366-10-1) and note reading on
multimeter.
(6)
If 24 vdc is not present, relace left or right
remote control cable (para 7-115 or 7-118).