e48A. ALL MARKER LIGHTS DO NOT ILLUMINATE IN NORMAL MODE (CONT)
CAUTION
Read CAUTION
KNOWN INFO
TEST OPTIONS
on following page.
6.
Continuity Test or
Circuit breaker CB67 OK.
STE/ICE-R Test #91
No marker lights illuminate.
Is continuity present from
Relay K20 OK.
REASON FOR QUESTION
relay K20 terminal 86 to
POSSIBLE PROBLEMS
If continuity is not present,
connector PX12 pin 5?
wire 1575 is faulty.
Faulty dashboard cable
assembly.
Faulty main light switch.
NO
Repair wire 1575 from relay K20 terminal 86
to connector PX12 pin 5 (para 2-45) or replace
YES
WTEC II dashboard cable assembly (para 7-10)
or WTEC III dashboard cable assembly (para 7-11).