TM 9-2320-366-20-1
(1) Disconnect batteries (para 7-57).
NOTE
Remove plastic cable ties as required.
(2) Remove two screws and washers from front
grille.
(3) Remove screw, washer, and front grille from
cab.
(4) Remove power distribution panel (PDP) cover
(para 16-2).
(5) Set multimeter to ohms.
(6) Connect positive (+) probe of multimeter to
terminal X3 on power distribution panel
(PDP).
(7) Connect negative (-) probe of multimeter to
terminal lug TL64 and note reading on
multimeter.
(8) If continuity is not present, go to step 6 of
this fault.
Change 1