Click here to make tpub.com your Home Page

Page Title: CONTINUITY TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-1
CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes. Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability. Check that
connector pins are not pushed back or not
capable of making good contact.
CONTINUITY TEST
(1) Remove instrument panel for access
(para 7-15).
(2) Disconnect connector J31 from connector
P31.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to connector J31 pin 21.
(5) Connect negative (-) probe of multimeter to
relay K11 socket 85 on PDP and note
reading on multimeter.
(6) If continuity is not present, repair wire 34
from relay K11 socket 85 on PDP to
connector J31 pin 21 (para 2-45) or replace
WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(7) If continuity is present, repair wire 34 from
connector P31 socket 21 to connector P34
socket 2 (para 2-45) or replace engine
control cable assembly (para 7-80).
(8) Connect connector J31 to connector P31.
(9) Install instrument panel (para 7-15).
(10) Install relay K11 in PDP.
(11) Install power distribution panel (PDP) cover
(para 16-2).
(12) Connect batteries (para 7-57).
Change 1
2-215

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business