TM 9-2320-279-20-1
Fuel System Maintenance Instructions (Cont)
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
(2)
Apply pipe thread sealing compound to threads of adapter (3), coupling (4), and connector (5).
(3)
Connect fuel return line (6) to fuel return line (7) with adapter (3), coupling (4), and
connector (5).
Change 8
4- 21
-