FRAME 3
Using 3/8-inch wrench, unscrew bleeding screw (1) 3/4-turn.
Soldier A
1.
Tell soldier B to slowly pump brake pedal three times and hold
pedal down after last pump.
Slowly pump brake pedal three times. Hold pedal down after last
2.
Soldier B
pump until told to let pedal up. Tell soldier A when pedal is being
held down.
3.
Look for air bubbles in hydraulic fluid in container (2). Using
Soldier A
3/8-inch wrench, screw on bleeding screw (1). Tell soldier B
to let brake pedal up and to fill master cylinder.
4.
Fill master cylinder (3) . Refer to frame 1. Tell soldier A when
Soldier B
master cylinder has been filled.
5.
Do steps 1 through 4 again, as often as required, until there are
Soldiers
no air bubbles.
A and B
GO TO FRAME
4
12-102

Privacy Statement - Press Release - Copyright Information. - Contact Us