TM 5-5420-279-23
3
2
1
4
5
a.
Remove
(1)
Support the weight of the relax mechanism cross member (1).
(2)
Remove the nyloc nut (5), washer (3) and bolt (5) securing the ball joint assembly (11) to
the upper relax mechanism cross member (1). Discard the nyloc nut (5).
(3)
Note the orientation and position of the ball joint assembly (11).
(4)
Remove the four nyloc nuts (9), washers (6 & 8) and bolts (10) securing the ball joint
assembly (11) to the relax mechanism slide housing (7). Discard the nyloc nuts (9).
NOTE
Note the position of and retain the spacers (2) and (12).
b.
Install
(1)
Fit the spacers (2) and (12) to the relax mechanism cross member (1).
(2)
Fit the ball joint assembly (11) in the position noted during removal.
(3)
Fit the bolt (5), washer (3) and new nyloc nut (4) securing the ball joint assembly (11) to the
upper relax mechanism cross member (1).
(4)
Fit the four bolts (10), washers (6 and 8) and new nyloc nuts (9) securing the ball joint
assembly (11) to the relax mechanism slide housing (7).