10. #1 and #2 EFIS power switches - Off.
11. BRAKE deice - Off.
*12. Battery condition - Check.
13. TGT - Check stabilized for 1 minute prior to
shutdown.
14. POWER levers - Flight IDLE.
15. PROP levers - FEATHER.
CAUTION
Monitor TGT during shutdown. If sustained com-
bustion is observed, proceed immediately to Abort
Start procedure.
16. CONDITION levers - FUEL CUT-OFF.
17. Oxygen system - OFF.
Do not turn exterior lights off until propeller rotation
has stopped.
18. EXTERIOR LTS switches - Off.
19. IR FLOOD light switches - Off.
20. COCKPIT LIGHTS MASTER switch- Off.
21. AVIONICS MASTER POWER switch- Off.
22. MASTER SWITCH - OFF.
2-83